(1)Product Exhibition
WTL Sintered wick heatpipe |
WTL Axial grooved wick straight heatpipe |
WTL Axial grooved wick elbow heatpipe |
(2)Product Parameter
Item |
Parameter |
Heat Pipe Length(mm) |
230~900 |
Container Materials |
Cu |
Capillary Structure |
Axial grooved wick / Sintered wick / Screen wick |
Working Fluid |
WTL Cooled Medium |
Designed Operating Temperature(℃) |
20~200 |
Designed Operating Inclination Angle(°) |
α> 5 |
Heat Transfer Capacity (Qmax) |
50~1000w (depends on the product specs) |
Isothermal Test |
When heating in 50℃ water bath, the temperature difference between Evaporator section and adiabatic section is less than 2℃ |
Heat Resistance (℃/W) |
< 0.08 (as reference) |
Principle of Heat Transfer Capacity Test |
|
Testing Requirements |
1)Heating input-power is supplied by the special delicate power adjustment; 2)heat pipe is placed with a α inclination angle; 3)when the fluctuate of the supervisory temperature on the outer shell is within 0.5℃ in 5min, the heat transfer process reaches its balance and the maximum heat transfer capacity (Qmax) is also defined simultaneously. |
(3)Sample Charts of Heat Transfer Characteristics Test
Fig.1 Heat Transfer Capacity Test of HP with 700mm Length |
Fig.2 Isotherm Test of HP with 700mm Length |